FITTINGS

Question:
Faulty Self-Closing Tap / Self-Closing Shower Valve

Answer:

Possible Cause
1. Water flowing non-stop

Check/Action/Solution
Clean cartridge, If fault still occurs, cartridge will need to be replaced.

Question:
Faulty Sensor Tap

Answer:

Possible Cause
1. Sensor Tap water flowing non-stop

Check/Action/Solution
Check and Clean solenoid valve

Possible Cause
2. Sensor Tap is not working

Check/Action/Solution
A. Check Incoming power supply
B. Check power controller output, replace if faulty
C. Check sensor eye, replace if faulty
D. Check solenoid valve, replace if faulty

Question:
Faulty Sensor Soap Dispenser

Answer:

Possible Cause
1. Sensor Soap is not working

Check/Action/Solution

A. Check Incoming power supply
B. Check power controller output, replace if faulty
C. Check sensor eye, replace if faulty
D. Check and adjust sensing distance using controller or remote control